Showing posts with label fermentation process control. Show all posts
Showing posts with label fermentation process control. Show all posts

Monday, March 31, 2008

WHEN TO START AND WHEN TO STOP A FERMENTATION PROCESS?



This is considered the "MILLION DOLLAR QUESTION" by all who run industrial fermentation process. Determining when to start and when to terminate a fermentation process is akin to playing shares on the stock market. The similarity between the two situations are the same. It is always very easy to start a fermentation process anytime but it is more difficult to determine the exact time to terminate the fermentation process.


If we terminate too early we might end up with lesser amount of fermentation products being formed and more raw substrates remaining underutilized by the microbes. If we terminate it too late, we might have higher amount of fermentation products formed and little or nothing of the raw substrate remaining in the fermentor (THEORETICALLY SPEAKING)

The catch is even though the second option seems more favourable but the cost of producing the fermentation products at the end part of the fermentation process will increase per unit of fermentation product formed.The rate of fermentation product decreases at the end stages but the costs of maintaining the fermentation in terms of time, energy will be higher.

The most important guideline to determine when to terminate the fermentation process will be ECONOMICS! Further in fermentation processes involving microorganisms even if we switch off the fermentation process, the process of fermentation is still active and on going in the fermentation vat
Read more!

Wednesday, February 20, 2008

WHY DID THE SAUERKRAUT FERMENTATION FAILED?- A LESSON IN IGNORANCE!


This is a true story of a food microbiology practical being conducted in one of the outstanding universities in the country which has gone awry, not due to the lack of instructions how to prepare sauerkraut but due to ignorance and poor understanding of fermentation technology

Although the steps are clear and all the components needed to produce the sauerkraut fermentation are followed, the practical failed.

Why the practical failed is easily understood if one understand the concept of fermentation technology. The lecturer who instructed the class in preparing the sauerkraut fermentation made two key mistakes:

1 Using a large Kilner jar to hold the fermentation process but it only contain very little food substrate and a large volume of head space
2 The kilner jars were regularly opened up and stirred like an open pot cooking

In such situations the fermentation will fail because of too much exposure to air and oxygen which will prevent proper fermentation of sauerkraut from taking place

It is hoped that lecturers or teachers intending to carry out such fermentation studies learn from their mistakes :)). It is very embarrassing to note lecturers with PhD still failed to carry out fermentation when their uneducated ancestors can do the fermentation properly Read more!

Friday, February 15, 2008

VALIDATION OF PROCEDURES IN FERMENTATION STUDIES


In carrying out any fermentation studies using any type of fermentor, it is of utmost importance that we carry out the studies properly so that there will be no unwanted errors and that the results obtained are proper and truthful. We do not want at the end of our fermentation studies ending up with wrong and erroneous data which in their true value are useless.

In the process of carrying out the fermentation we need to look closely at the following points

NEED TO CALIBRATE THE ELECTRODES
------------------------------------------------
In carrying out fermentation studies we are dealing with fermentors which often come with various sensors and electrodes to monitor the fermentation process. The electrodes need to be examined closely in terms of its structure and functionality. It is important to calibrate the electrodes before every use in the fermentation studies

Most forget that every electrode have its life time expectancies especially in the fermentation studies where the conditions are harsh and demanding and the lifespan of the electrodes are short

It is ad to note in certain incidence fouled, broken and dried electrodes are used to monitor the fermentation process

NEED TO ESTABLISH ASEPTIC INTEGRITY OF FERMENTOR
-----------------------------------------------------------------
Before the use of the fermentors close examinations must be carried out on the various components of the fermentors from tubings to air filters. Blank run using rich medium should be used to detect if the fermentor is fit for operation.

NEED TO STERILIZE PROPERLY
-----------------------------------
The autoclaves used to sterilize the fermentors should be validify in terms of their efficacy in sterilizing the fermentor. The inner chamber temperature of the autoclave should be calibrated to ensure that the temperature shown outside is the same as shown inside. This is similarly applied for the pressure check.

There is the need that the autoclave is not over loaded with materials to be sterilized, if not the sterilization cycle need to be adapted

NEED TO USE UNCONTAMINATED PURE CULTURES
-------------------------------------------------------------
It is bad to assume that the microbial cultures used for the fermentation to be pure. Microbiological checks are need to be carried out up stream before the culture is used. Failure to do this would be a disaster to the fermentation studies as amplification of contaminants could occur with time length and temperature


NEED TO CARRY OUT PROPER ASEPTIC TECHNIQUES
-----------------------------------------------------------
Proper aseptic techniques during inoculation and sampling should be effectively carried out and confirmed or validated. The sampling line is one of the most common portals for the introduction of contaminants into the fermentor.

NEED TO USE CORRECT OR APPROPRIATE VOLUME OF BROTH
-------------------------------------------------------------------

The volume of fermentation broth should be calculated to take into account of possible loss through samplings and dehydration. It is important that the volume filled must not enter or use up the headspace to avoid contaminations

Wrong volume of broth used could affect the results of the fermentation studies. We must be efficient and economical in determining the right volume for the fermentor

DON'T ASSUME
------------------
In most of the procedures above we must not assume or live in the belief that everything is proper and assuming that the fermentors are effectively sterilized, or that the cultures are not contaminated or the ph probe is working well as specified. There is the need to validate that all the procedures are correct and the probes are in 100% tip top conditions.

Studies or validation procedures must be carried out to confirm all the above steps. Validation of equipments or methods constitute part of HAACP procedures and cGMP mechanisms. It is sad to say that these very important and fundamental objectives are often not carried out especially if the fermentation process involves engineers.

This condition would not be acceptable in stringent and demanding industries such as in pharmaceutical fermentation industries

RESPONSE FROM FERMENTOR USERS
------------------------------------------
I have expressed my concern to a number of fermentator users in the local colleges and universities and inquire of the status or procedures carried out in their respective plants or laboratories. Sad to say the response have been very very poor from no response to a one word answers. This attitude does reflect the sad attitude of not willing to learn or scared of being criticised Read more!

Wednesday, February 13, 2008

ANAEROBIC DIGESTORS- OPENING UP PANDORA'S BOX


The use of anaerobic digestion process in biological wastewater treatment has often been hailed as the ultimate answer in the treatment of various types of wastewaters. There are many advantages cited in using this fermentation technology such as wastewater stability, sludge reduction, dewaterability, energy and fertilizers. Yet such attractive technology that is in the dreams of environmental engineers are often the 'nightmare' of wastewater operations,

The sad truth is the anaerobic digestion process is very sensitive and instable process and easily prone to failure..

The failure of control of the anaerobic digestion is often attributed to the failure of understanding the microbiology and biochemistry of the process

ANAEROBIC DIGESTION AS COMPLEX FERMENTATION
--------------------------------------------------------------
The anaerobic digestion is a very complex fermentation process because:

1 It is a mix culture microbial populations all involving in the process
2 It is made up of two basic groups of microorganisms; acidogens and methanogens with their own physiological attributes requiring their own specific growth requirements but still dependent on each other in the anaerobic digestion process
3 Methanogens are obligate anaerobic bacteria very fragile, slow growers and easily killed by exposure to oxygen and other extreme conditions
4 Complex substrate loading to the anaerobic digestors
5 Very high solid content and complex rheology of the substrate
6 Poor mixing conditions pf most anaerobic digestors
7 Washouts and slug dosings or shock loadings affecting the bacteria
8 Effect of temperature and ph upon the two groups of microorganisms

OPERATION OF ANAEROBIC DIGESTOR AND CLOSE MONITORRING
-----------------------------------------------------------------------
Since one of the hall,arks of anaerobic digestion process is its sensitivity and stability, the success of its operation depend on close monitoring of the anaerobic digestion process. The optimu operating characteristics of an optimally run anaerobic digestor are marked by:

1 High volume of gas production
2 High percentage of CH4 to CO2 ratio
3 Neutral pH
4 Very low concentration of TVFA of less than 200mg/litre
5 Presence of short chain fatty acids such as acetic and propionic acids with little or no trace of butyric and valeric acids

The optimal range occurs in a very narrow range thus close monitoring are required to detect any changes and to take detection before the impending disaster

It should be noted that the TVFA profile is not the cause of a digestor failure but symptoms of the inefficient and uncoupling of the anaerobic digestion process between the acidogens and methanogens Read more!

Tuesday, February 5, 2008

SCIENTIFIC APPROACH TO DETERMINE PROBLEM AREAS IN BIOLOGICAL WASTEWATER TREATMENT PLANTS


Most, if not all, biological wastewater treatment plants are either not working or are not functioning efficiently to their expectations. This sad state of affairs gets worst with time due to changes in the operating parameters of the WWTP or due to poor monitoring and servicing of the WWTP.

The main contributing factor to this poor state of WWTP probably arises out of the attitude of the companies regarding the WWTP as a liability in that it does not contribute to the profits of the company. It is not surprising therefore that they will not invest more money in operating and maintaining the WWTP efficiently. In the first place they build the WWTP more as an excuse to get the necessary operating license to carry out their manufacturing activities

The WWTP has always been situated at the back of their manufacturing premise and not in front of their minds. The full realization and impact of poor housekeeping in maintaining an operating WWTP only comes too late when Department Environment officers slap them with compounds and threatening imprisonments and forced transfer of their manufacturing facilities

FAILURE OF WWTP

The failure of WWTP could be attributed to many factors such as design oversights, poor operation, poor maintenance and servicing of the WWTP. These various failures will ultimately affect the performance of the microbes in the WWTP which will ultimately affect the performance of the WWTP. After all a biological WWTP is nothing more than a bioreactor that support the growth and function of high concentration of microorganisms

NATURE AND CLUE FROM FAILURES

WWTP failures reflect both the state of the pathology of the WWTP and give us vital clues to the where and why the WWTP fails. We should try to study the nature of these failures scientifically so that it will aid us in our decision whether we can repair, replace or improved the WWTP process. Failing to do this we might end up in the future building or renovating the WWTP which will end up in similar predicament years later

MAIN TYPES OF FAILURES

There are generally failure two main types of failures:

1 Sudden failure

2 Gradual failure

Sudden failure of WWTP is a failure that is not anticipated and usually occurs immediately beyond our control. Examples of sudden failure are electrical outage, blower burnt out, toxic chemicals or sudden hydraulic loading due to heavy rain. The impact of sudden failure is often very serious which can throw out the WWTP out of its function

Gradual failure of a WWTP occurs slowly and show cumulative deterioration with time. It is usually reflective of slow breakdown of system. Example of gradual failure of WWTP is exemplified by gradual clogging of the porous filters used in supplying air to the WWTP. Such failures could have been averted as the signals of impending failure are there. Such failures could have been avoided if remedial actions such as repair taken before turning to disaster

Previous records if kept could have indicated clues of impending failure, when the performance of the WWTP is slowly spreading out of optimum band state of operations. We should be able to see the loss in treatment efficiency of the WWTP over time in terms of BOD, COD and TSS reduction

WHY MOST WWTP FAILURES GO UNDETECTED?

In reality most failures go undetected because there are no staffs that are trained to monitor the performance of the WWTP. By the time the WWTP completely broke down, it is already too late to take preventive actions

Even if monitoring of the WWTP is carried out, it usually involves ‘end of pipe’ analyses and not ‘up pipe’ or ‘along pipe’ analyses. In most cases the analyses just involved the basic regulatory requirement parameters such as BOD, COD and TSS. These parameters are insufficient to show the state of health of the WWTP and you do not really know which unit process is facing the problem?

IMPORTANCE OF ADDITIONAL PARAMETERS MONITORING

There are other parameters besides BOD, COD and TSS to give us the clues on the exact state of health of the WWTP. Any changes in the operating parameters of the WWTP will be reflected by the gradual change in the composition and properties of the microorganisms of the WWTP. There will also be changes in the chemical; parameters in the mixed liquour due to the changes in the microbial consortium in the WWTP.

The failure for nitrification could be indicated by very poor DO and high NH3 content of the wastewaters. High biomass washouts could be attributed presence of pin flocs within the WWTP are some of the examples of how additional parameters monitoring help to determine WWTP failures


SCALEDOWN EXPERIMENTS

To confirm the observations there might be the need to carry out scale down studies to pin point the cause of the WWTP failure. Samples of the mixed liquour from the WWTP are removed and transferred to various smaller vessels to study the effect of mixing, aeration or oxygen uptake. From the studies we can conclude if enough mixing or aeration are the culprit of the WWTP failure.

Additional respirometric experiments may be carried out to determine if the microorganisms are viable or if the wastewater is biodegradable.


NEED TO DO PROFILE STUDIES OVER THE SERIES OF UNIT PROCESSES IN WWTP

Wastewater treatment in a WWTP usually involves the flow of the wastewater through a series of unit processes which include physical and biological treatment

Analyses of various parameters as the wastewater enter and leave the various unit processes from the influent inlet to the treated effluent outlet will be able to tell us:

1 Which unit processes are most effective in reducing the pollution load?

2 Which unit processes are the rate limiting steps and controlling the bottleneck of the process?

3 Which unit process are the ones having problems?

This information would be useful to allow us to improve the efficiency of the unit process in mind or even to increase the optimum rate to the limit for existing functioning unit processes

IN SITU AND ON SITE MEASUREMENTS
Simple measurements can be conducted by using ph and DO probe with long cables, together with simple tracer studies to see the problems of flow and circulations within the WWTP. Any short circuiting or improper mixings of the WWTP will be easily noticed

STITCH IN TIME
The success in determining the cause of plant failure and inefficiency will allow rapid action to remedy the situation or even to optimize the rate limiting steps in the wastewater treatment process. This will allow the factory to save time and costs.

If the failure is not detected immediately and the WWTP is allowed to deteriorate until whole system backfire then it will be difficult to pinpoint source of error and to repair it early.

Read more!

Monday, February 4, 2008

FERMENTATION PRODUCTS- CHEMICAL VERSUS MICROBIOLOGICAL SYNTHESIS


The common thing shared by both chemical synthetic industries and the microbial fermentation industries is that both are involved in the synthesis and production of chemical compounds. That is where the similarity ends.

Chemical industries produced both organic and inorganic chemicals in more varieties by carrying out the chemical reactions which utilize more energy and pressure compared to the fermentation industries. Microbial fermentation industries carry out the synthetic reactions under normal ambient temperature and pressure using microorganisms and enzymes to catalyze the changes. Their biological reactions do not require high energy or extreme conditions.

Fermentation products formed by the microorganisms are however more labile and occur in lower concentrations or in very dilute solutions. These characteristics have created problems not only in the production of the chemicals but also in the downstream isolation, concentration and purification of the fermentation products compared to the chemical industries.

It is interesting to note that most of the chemical downstream processing units for product recovery are also used in the fermentation industry downstream processing of chemical oroducts. However, in the case of downstream processing of fermentation products additional downstream processing units are added in the purification and concentration of fermentation products. Read more!

Tuesday, January 22, 2008

WHEN ENGINEERS AND BIOLOGISTS COLLIDE!


It is common to see that in such a highly integrated field of biotechnology and industrial microbiology where there is suppose to be a fusion or input of knowledge between microbiologists and bioprocess engineers we have a situation where both parties do not really see 'eye to eye'. This has more than often resulted in process failure or the bioprocess do not really run as the targeted expections.

PENICILLIN FERMENTATION
----------------------------------

In the history of penicillin fermentation or any other antibiotics, the progress in design of fermentors have been slow or static. In fact there is not much change in the design of CSTRs until now. Nor has the engineering designs improvements yield drastic improvements in the penicillin yield! The increase in the yield or productivity of penicillin fermentation has been more to the improvement of the strain by geneticists, biochemists and microbiologists!!

WASTEWATER TREATMENT IN BIOREACTORS
----------------------------------------------------
A very good example is seen in the design of bioreactors such as bioreactors used in biological wastewater treatments. Bioreactors in biological wastewater treatments are often considered the biggest man made bioreactor using mixed cultures and operating continuously under septic conditions.

It is really hard to see wastewater treatment plants working efficiently and most bioreactors ending up by not performing to the expectations

There are valuable lessons to be learnt from this situation. For decades it seems that the engineers have a field day designing, building and operating the various biological treatment plants. The engineers only see the process as a " simple engineering" process, whereby there is input of substrate into the bioreactor, and where the microorganisms are present easily working themselves out happily eating away the pollutants thus treating the wastewaters. They only describe the process by a few key parameters which they think and understand to operate and control the bioreactors. Usually the standard parameters are BOD, COD, SS among others,

They do not see there is the need to understand the various biological and biochemical processes occurring in the biological reactor. As far as they are concerned, they designed the bioreactors more as the structure and volume to hold a certain effective volume of wastewaters over a certain designed hydraulic retention time.

Sad to say in such designs they only use the so called standard calculations from standard engineering texts in civil engineering. They do not take into considerations the:
1 Type of microbes and biochemical reactions that will be taking place as function of time or space
2 The supply and utilization of oxygen by the microorganisms in the bioreactor
3 Adaptation and wash out rates of microorganisms
4 Effect of toxicity and cumulative effects of toxic conditions
5 Nutritional and physiological needs of the various microorganisms
6 Behaviour of the populations of microorganisms in the bioreactor

The way they act as if nothing bad will ever happened or that all the bad processes will be taken care by GOD or blame it on poor understanding and managing of the treatment plants by the plant technicians.

In a way, we cannot blame this situation from happening as what is important is that the factory or the plant must have a biological treatment plant to get a certificate of fitness or license to operate. Whether it work or not is secondary and not the problem to the engineers that build the treatment plant

Why do most treatment plants fail after some period of operation? In the first place we see the whole scenario of the plant failure as a chain reaction of errors starting from poor engineering design and operation which will ultimately affect the performance of the microorganisms leading to poor treatment of the wastewaters. It should be noted that with just any process the range of optimal operating conditions in wastewaters operate within a very narrow babd of operating conditions. Change in any operating parameter will either lead to changes in the activity of the microorganisms , or worst still the change will affect the change of many other parameters either simulataneously or linearlr in a series of related events.

Changes to the process can either be immediate such as ' poisonings' which will kill the microorganisms or the failure of blowers leading to immediate anaerobic conditions that will result in abrupt plant failure. The second change occur slowly and cumulatively over a long period which will lead to gradual process failure

It is strange that if we surf the internnet and look at the various suppliers and contractors that sell or build the various biological treatment all GUARANTEE that their biological treatment plants will work wonderfully! Just you wait and you will see if such claims are true. As Tsun Zu the millitary strategist said once " In war, you win by deception". Business is war! They will promise you everything until you installed the tretment plant.

It is amazing in a few sites of suppliers and contractors of aerobic biological wastewater treatment plants they will tell certain parameters such as BODm COD and SS but failed to indicate the Dissolved oxygen readings of their treatment plants!!!!! Mind you we are talking about processes that uses oxygen.

They dont bother coming clean. All they bother telling you is their magnificient track record of having built this and that at here and there. Rarely will they give you the data of the actual plant or lab performance feaibility studies! What you will get are promises and 'guarantees' that it will work!

I cannot see why they dont give the other additional data parameters as the wastewaters go through the various unit processes so that the customer can assess the data themselves or employ an INDEPENDENT CONSULTANT to vet the technical data? This would have ensured the buyer that they are not cheated and will be getting good value for their money and freedom from future headaches?

Maybe the engineers 'hate' the microbiologists for their ability to see the process. Or is it because they think they are righter than God? or they are always correct?
If this is so why do most....MOST..... MOST treatment plants failed?

The point is while it is true engineers are trained to design and build these bioreactors, they must really try to understand the processes that is occurring in the bioreactor to come up with better design. It is time they stop the bad habit of designing treatment plants based on the number of PE for loadings pf the treatment plant or reduction of BOD and COD based on some standard references

Major designs like this must involve feasibility and technical studies to ensure that the treatment plant really will work and their range of test loads Read more!

TALKING TO THE MICROBES


The microorganisms in the fermentors or bioreactors are 'talking' to us. But most of us cannot appreciate how they are talking to us! By listening carefully to them, they are telling us whether they are dying, being poisoned, suffering from malnutrition or they are sick and need us to help them.

We as the fermentation technologists must try to understand them by understanding how they talk to us or reading their signals on how they are..The knowledge will help us guide the fermentation process to a successful completion


The most important way the microorganisms are communicating with us is by measuring and analyzing their respirometric data. Respirometry is a measure of their 'breathing'.

Aerobic microorganisms use oxygen in the process of breathing and releasing carbon dioxide as their metabolic products. If the microorganisms are active they will show active respiration by high rates of oxygen utilization

If they are 'sick' or old, they will not respire that actively. If the number of microorganisms are too little so will be the rate of respiration. If the microorganisms are exposed to new or difficult substrate the rate of biodegradation will reflected in their respirometric data

The ability to analyze their respiration must be supported by other data or parameters before reaching the right conclusion

Just like a good physician, a simple stethoscope examination will yield a lot of data regarding the state of health of the patient. To a poor physician the stethoscope will not yield much.... Read more!